BPPFR - PR1422 B-2, PART A

Product Identification

Product ID:PR1422 B-2, PART A
MSDS Date:06/26/1991
FSC:8030
NIIN:01-154-9246
Kit Part:Y
MSDS Number: BPPFR

Responsible Party
PRODUCTS RESEARCH & CHEMICAL CORPORATION
5430 SAN FERNANDO ROAD
GLENDALE, CA 91209
US

Emergency Phone: 800-424-9300(CHEMTREC)/800-228-5635

Info Phone: 818-240-2060

Preparer: JCS

Cage: DO563

Contractor
PRODUCTS RESEARCH & CHEMICAL
1800 GLENDALE, CA 91209 US

Telephone: 818-240-2060

Cage: DO563

Ingredients

DIMETHYLACETAMIDE (DMAC)

CAS: 127-19-5

RTECS: AB7700000

Fraction By Weight: 20%

OSHA PEL 10 PPM (SKIN)

ACGIH TLV: 10 PPM (SKIN)


CALCIUM DICHROMATE

CAS: 14307-33-6

RTECS: HX7630000

Fraction By Weight: 15%

OSHA PEL 0.1 MG/M3 (CEILING)

ACGIH TLV: 0.05 MG/M3 (AS CR)


MAGNESIUM DICHROMATE

CAS: 13423-61-5

Fraction By Weight: 5%

OSHA PEL 0.1 MG/M3 (CEILING)

ACGIH TLV: 0.05 MG/M3 (AS CR)


HYDRATED ALUMINUM SILICATE

CAS: 1335-30-4


WATER

CAS: 7732-18-5

RTECS: ZC0110000


SILICON DIOXIDE

CAS: 67762-90-7

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES: IRRIT, POSS EYE DAMAGE. SKIN:
IRRIT. PROLONG EXPOS-POSS ALLERGIC SKIN RASH. TOXIC BY SKIN ABSORB.
LAB TEST-DERMAL APPLICATION OF DMAC TO PREGNANT RATS PRODUCED FETAL
ABNORMALITIES. PROLONG EXPOS TO HEXAVALENT CHROMIUM COMPOUNDS OVER
PEL-POSS PAINLESS PENETRATING ULCERS OF THE SKIN. INHAL: (MIST/DUST
OF DRIED*
Explanation of Carcinogenicity:CHROMIMUM COMPOUNDS IS ON CALIFORNIA
LIST OF CHEMICALS KNOWN TO CAUSE CANCER.*(MATERAIL) IRRIT OF MUCOUS
MEMBRANES**
Effects of Overexposure:**.MAY CAUSE BRONCHO ASTHMA.(VAPOR)
IRRIT/NAUSEA/HEADACHE/WEAKNESS/POSSIBLE LIVER DAMAGE.PROLONGED
EXPOSURE TO HEXAVALENT CHROMIUM COMPOUNDS OVER THE PEL MAY CAUSE
PENETRATING ULCERS OF THE MUCOUS MEM BRANES OF THE NOSE AND
PERFORATION OF THE CARTILAGINOUS NASAL SEPTUM.INGEST; IRRIT OF
STOMACH & INTESTINES.NAUSEA,***
Medical Cond Aggravated by Exposure:***VOMITING AND DIARRHEA.POSSIBLE
LIVER AND KIDNEY DAMAGE.

First Aid

First Aid:EYE: FLUSH WITH LUKE WARM WATER FOR 15 MINUTES, CONSULT A
PHYSICIAN. SKIN: WASH WITH SOAP AND WATER. IF SYMPTOMS PERSIST,
CONSULT A PHYSICIAN. INHALATION: REMOVE TO FRESH AIR. IF SYMPTOMS
ARE PRESENT CONSULT A PHYSICIAN. INGESTION: CONSULTA PHYSICIAN.

Fire Fighting

Flash Point:150F COMBUSTIBLE
Extinguishing Media:CO2, DRY CHEMICAL, FOAM, WATER FOG
Fire Fighting Procedures:USE COMPLETE PERSONAL PROTECTION

Accidental Release

Spill Release Procedures:DIKE AND COVER THE SPILL WITH A NON-OXIDIZABLE
ABSORBANT. SCOOP INTO CONTAINER. SPRINKLE SODIUM THIOSULFATE ON
RESIDUE. WORK INTO RESIDUE. SCOOP INTO DISPOSAL CONTAINER. CLEAN
AREA WITH WATER.

Handling

Handling and Storage Precautions:WASH THOROUGHLY AFTER HANDLING AND
BEFORE SMOKING OR EATING. AVOID INGESTION. DUE TO TOXICITY BY SKIN
ABSORPTION, AVOID ALL SKIN CONTACT. THIS
Other Precautions: PRODUCT CONTAINS A TOXIC CHEMICAL OR CHEMICALS
SUBJECT TO THIE REPORTING REQUIREMENTS OF SECTION 313 OF TITLE III
OF THE SUPERFUND AMENDMENTS AND REAUTHORIZATION ACT OF 1986 AND 40
CFR PART 372.

Exposure Controls

Ventilation:GENERAL VENTILATION TO MAINTAIN VAPOR BELOW PEL.
Protective Gloves:NITRILE, BUTYL OR NATURAL RUBBER GLOVES.
Eye Protection:CHEMICAL GOGGLES OR FULL FACE SHIELD
Other Protective Equipment:SKIN AREAS SUBJECT TO SPLASH SHOULD BE
PROTECTED W/NITRILE, BUTYL, NATURAL RUBBER, POLYETHYLENE APRON OR
COVERALLS.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING AND BEFORE
SMOKING OR EATING.
Supplemental Safety and Health

Chemical Properties

Spec Gravity:1.40
Solubility in Water:COMPLETE
Appearance and Odor:BLACK LIQUID
Percent Volatiles by Volume:55

Stability

Stability Indicator/Materials to Avoid:YES
EASILY OXIDIZABLE MATERIALS
Hazardous Decomposition Products:OXIDES OF CARBON AND NITROGEN;
CHROMIUM COMPOUNDS

Disposal

Waste Disposal Methods:EPA WASTE NO. D-007. DISPOSE OF SPILLAGE IN
COMPLIANCE WITH FEDERAL AND STATE REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.